3 years Diploma in Electrical from mountain institute of Management & technology Delhi .2008
6 month scheme of community polytechnics from deoria in 2006
High School from U.P. Board, Allahabad with 59% in 2005.
EBM M/c- Make - CMP 2+2, Sikka 2+2 , milacron 2+2 , Vinita, Jagmohan, mouser etc.
Pet Blow moulding M/c- Make - ASb 50MB, ASB 12M, ASB 70DPH , 70 DPW
IBM M/C Make - victor
Injection Moulding M/c- Make - Omega Feromatic, Battenfeld, electronica, toshiba, Gold coin, L&T . 75 ton to 550 ton etc.
Turfline & Sheet line M/c. Make- Toshiba
HDPE & PVC Pipe M/c. Make - Cincinnati battenfeld, Unicor, luigi Vendera, Kraussmaffei berstorff, Kabra Extrushiontechnik etc. Pipes od make - 20 mm. To 1200 mm.
Water Chiller air & water cooled - Reynold, Blue star, Voltas, kirloskar, Green box, prasad koch, 10 TR to 150 TR etc.
Air Compressor (LP) Atlas Capco,Chicago pneumatic, Elgi, 70 Cfm to 1300 cfm etc.
Air Compressor (HP) , Chicago pneumatic 196 Cfm to 512 cfm etc
Power press- Singhal power pess.100 Ton.
D.G Set- Cummins, Volvo penta, kirloskar, 15 kva to 1500 kva etc.
AHU & MSP make - samsung, systemair up to 12000 CFM.
Cooling tower make - Advance, national up to 350TR.
Spary
Sr. Engineer Maintenance
From - 16 April 2019 to till date.
Company profile -India's largest rigid plastic packaging company
Sr. Maintenance Engineer
From - 1jan 2018 to april 2019 date.
Company profile -manufacturing of polymer & Composite products.
Maint.engine
From - Sept.2014 to 30dec. 2017.
M/s.Duraline India pvt Ltd
Job profile -
Document control, Power reports, System Analysis and Completion reports
Experience in Power transformer Troubleshooting & Maintenance of 2 MVA 33/0.440KV.
Experience in Troubleshooting & Maintenance of H.T. & L.T. Panel.
Working Experience with ABB make 1600 Amp SF6 33KV breaker .
Working Experience ACB make -ABB , L&T, schinder, and Siemens 800 to 4000 Amp.
Experience in the installation, termination, troubleshooting and maintenance of A. C.
systems, Variable frequency drives make ABB, Siemens, Danfoss,kirloskar, Schneider, 1.1 kw to 220 kw installation, troubleshooting and preventive maintenance of Control & Power panels.
Experience in machine installation, commissioning, preventive, predictive, Break down Maintenance.
Experience in maintain of utilities like pumps,air compressor, chillers, DG set, Day to Day trobuleshooting and record keeping.
Experience in Troubleshooting & maintenance of PLC based most modern machines.
Work closely with project managers, team leaders and other project team members.
Experience in control of electrical & machinical spear parts consumption & consumble.
Knowledge to poka , yoke , kaizen , root cause analysis.
Knowledge to MTBF, & MTTR ,OEE, TPM etc.
Manpower deployment at project installation and managing them.
Experience in Troubleshooting & Maintenance of Fully Automated.
Experience in quality, production & manpower with team.
Copyright © 2003 - 2015 Smartech Global Solutions Ltd. All rights reserved. Designed by Plastemart.com