plastemartjobs.com Email: jobs@plastemart.com, hr@plastemart.com Download Date: 6/1/2025 7:15:43 PM ________________________________________________________________________________________ RefNo: CA - 29932 Gender: Male Age: 36 Designation: Senior Maintenance Engineer Highest Education Level: Graduate - Degree Preferred Location: Mumbai Notice Period: 30 Days Education Details: BE (Electrical) Navsahyadri Education Society Faculty Of Engg.Bhor, Pune June 2016 Pune University with 59.18% in 2016 Diploma (Electrical) Smt. sharadchandrika Suresh Patil Inst. Of Polytechnic. Chopda Mumbai University with 69.00% in 2010 HSC Pratap college Amalner Nashik with 61.84% in 2007 SSC Sane Guruji Nutan Madhyamik Vidyalaya, Amalner Nashik with 55.20% in 2005 Skill Sets: COMPUTER KNOWLEDGE Safal And Excel . Fensis (ERP) Microsoft Word, Excel, Power Point. State Level Paper Presentation -HVDC Transmission. Work Experience: 10 Work Experience Details: Senior Maintenance Engineer From April 2019 to Till date Company profile- manufacturer of critical application NVH Parts, Rubber Parts, Casting & Plastic products for various Industries such as Railway, Automotive Job profile- Operational head for 900KVA transformer installation (without shielded). Operational head for 500 KW & 1000KW Furnace (ELECTROTHEM) installation. Operational head for DUST Collector, Mixer, Knock out unit (JK). Operational head for PUMP HOUSE, DM Water unit Capacitor rack. (ELECTROTHEM) Operational head for AUSTEMPRING , ACB, CRANE, SHOT BLASTING. Operational head for AIR COMPRESSOR, PHELTING SHOP. Operational head for HEAT TREATMENT FURNACE (BOGGI FURNACE). INJECTION RUBBER MOLDING ? DESMA , JINGDE COMPRESSIVE MOLDING - REP TUNGE BANBERRY, MIXING MILL Mandatory Documents & Records Required by IATF 16949:2016 Preventative Action Records (Clause 6.1.2.2) Maintenance and Calibration Record (Clause 7.1.5.2.1) MTTR, MTBF, TPM, Availability, OEE, Planned Maintenance. Scheduling &Implementation of Preventative & Predictive Maintenance. Maintain the History Card, Critical Spare Part,& M/C Breakdown Record. Maintain The Machine Related Regular Spare Item. To Prepare Daily Consumption Of Electricity & Fuel. Proper Documentation As Per Regulatory Requirement. Troubleshooting All Equipment Breakdown & Repairs As Needed. Perform Shop Floor Maintenance Activities According To The Priority Of Production. Maintenance Engineer From (June 2016 to April 2019) From ( Sep 2012 to Aug 2013) Company profile- Manufacturing the safest, innovative and cost effective packaging for the pharmaceutical industry. Job profile- Maintenance of INJ, BLOW, EXTRUSION, DG, Air Compressor, Chiller, AHU, Maintenance of DG set 125KVA. Utility installation & Maintenance Air compressor. Maintenance of Pump House & Fire Fighting system. Knowledge of PM daily activity report and electrical consumption report. Knowledge of maintain breakdown Maintenance & Required Tools. Documentation of maintenance, ISO 9001:2008. Having good knowledge of HVAC. EBM ? Extrusion blow molding electrical, mechanical and hydraulic, pneumatic maintenance. Daily report to PM plan & Breakdown Maintenance to HOD. Assessment of the required tools for the maintenance of the equipment. INJ, IBM, EBM, molding machine maintenance (plastic molding). Drive maintenance. (not programming repair) Maintenance of Electrical and Electronics Components HOT Runner card. Utility installation & Maintenance screw Air compressor. Knowledge of Cooling Tower, Bus Duct. EMS14001-2004 & OSHAS 18001-2007 documentation updating Operation & maintenance Electrical distribution system. Responsible for day to day activity of Utility & breakdown Handle. IBM ? injection Blow Molding electrical, mechanical and hydraulic, pneumatic maintenance. INJ ? Injection molding electrical, pneumatic, mechanical maintenance. Wadding machine maintenance INJ ? cap vision system machine Knowledge of product quality and a product selection, Maintenance Engineer From Aug 2010 to Sep 2011 BOSCH CHASSIS SYSTEMS INDIA LTD.JALGAON Job profile- Electrical Preventive Maintenance and Breakdown attended. Maintenance of Electrical and Electronics Components fuse, transistor, MCB. Operation & Maintenance Electrical Preventive Maintenance. Thermocouple & Heater Calibration. Operation & Maintenance of DG set 125KVA, Maintenance of Screw Air Compressor. Maintenance of HVAC and compressor. Utility installation & Maintenance Water pump, Cooling Tower. Maintenance of Pump House & Fire Fighting system. Fire Loss risk protection & prevention ? Fire Pump, Sprinkler, Smoke Detection, Fire Extinguisher system. Documentation of maintenance, ISO 9001:2008. DG & Chiller plant set. HT switch-gears consist of Sf6 breakers. Assessment of the required tools for the maintenance of the equipment. INTERESTING AREA Maintenance Quality control Future Goals: I am interested to work in a very competitive environment where I could apply my knowledge, skills and energy to the best of my potentials with full determination and sincerity. ________________________________________________________________________________________